Treated Fresh Air Unit Manufacturers in Assam
100% Fresh Air Treatment & Energy Recovery Solutions
Treated Fresh Air Units are designed to circumstance, dehumidify, filter out, and supply outside air into occupied spaces. Treated Fresh Air Unit Manufacturers in Assam can offer committed outside air systems for industrial buildings, healthcare centers, pharmaceutical areas, hotels, and educational areas. EUROCON TFA devices take care of 1,000-50,000 CFM airflow, with static pressure up to 1,800 Pa and cooling or thermal duty from 4.0 TR to 140 TR.


TFA (Treated Fresh Air Unit) — 100% Fresh Air & Energy Recovery DOAS
Each TFA (Treated Fresh Air Unit) is manufactured at Eurocon's state-of-the-art facility using CNC laser cutting, automated lock-forming, and precision structural engineering to ensure minimal casing leakage and maximum lifecycle reliability.
What Is a TFA Unit?
A TFA unit treats 100% outdoor air before it enters a building. The system can combine energy recovery, multi-stage filtration, cooling, heating, and dehumidification to fulfill the desired fresh-air conditions.
For projects requiring dedicated outdoor-air treatment, a Treated Fresh Air Unit Manufacturer in Assam can configure rotary enthalpy wheels, cooling coils, filtration banks, fans, and dampers according to the MEP layout. EUROCON's enthalpy wheel can obtain up to 75% sensible and latent exhaust energy.
Construction & Insulation
EUROCON TFA devices are available in single- or double-skin casing. The double-skin construction makes use of 25 mm or 50 mm injected PUF insulation with a density of 40 kg/m³ and thermal-smash profiles.
Manufacturing includes CNC laser cutting, automatic lock-forming, and precision structural engineering to help low casing leakage and long-time period reliability. Treated Fresh Air Unit Manufacturers, Assam also can configure heavy-gauge anti-corrosive construction in which the installation environment calls for additional safety.
Treated Fresh Air Unit Suppliers in Assam
Heat Recovery, Cooling & Filtration
These methods are the utilization of a rotary complete enthalpy wheel, a sensible heat wheel, or run-around coil loop for recovery. Filtering may be with EU4 pre-filtration, EU7/EU9 advantageous filtration, carbon filtration, or terminal HEPA filtration.
For fresh-air systems with unique indoor-air-super requirements,Treated Fresh Air Unit Suppliers in Assam can configure chilled-water, DX refrigerant, heat-water, or electric-heater arrangements. Modulating face and pass dampers also are available for economizer loose-cooling operation.
Key Features
- 1,000-50,000 CFM airflow
- Static pressure as much as at the least 1,800 Pa
- 4Zero-140 TR cooling/thermal duty
- 1,700-85,000 m³/h airflow quantity
- 25/50 mm injected PUF insulation
- 40 kg/m³ PUF density
- EU4 + EU7/EU9 filtration
- Optional carbon and HEPA filtration
- 6-row/8-row copper-tube coils
- Hydrophilic fins
- Direct-drive EC plug fan
- V-belt centrifugal fan choice
- 2.2-75 kW motor range
- IE3/IE4/IE5/EC motor options
- Operating temperature from -10°C to +55°C
These options allow a Treated Fresh Air Unit Supplier in Assam to healthful the unit with the desired airflow, pressure, filtration grade, thermal duty, and energy-recovery arrangement.
Technical Specifications
| Parameter | Specification |
|---|---|
| Airflow | 1,000–50,000 CFM |
| Air Volume | 1,700–85,000 m³/h |
| Static Pressure | Minimum 1,800 Pa |
| Thermal Duty | 4–140 TR |
| Casing | 25 / 50 mm Double-Skin, Injected PUF |
| PUF Density | 40 kg/m³ |
| Filtration | EU4 + EU7 / EU9; Carbon / H14 HEPA Optional |
| Coil | 6 / 8-Row Copper Tubes with Hydrophilic Fins |
| Fan | Direct-Drive EC Plug Fan / V-Belt Centrifugal |
| Motor | 2.2–75 kW, IE3 / IE4 / IE5 / EC |
| Operating Temperature | −10°C to +55°C |
| Energy Recovery | Up to 75% Sensible & Latent Exhaust Energy |
| Cooling Options | Chilled Water / DX |
| Heating Options | Hot Water / Electric Heater |
The technical range offers Treated Fresh Air Unit Suppliers, Assam flexibility to increase systems for different construction sizes, air-quality requirements, cooling loads, and airflow processes.
Treated Fresh Air Unit Exporters in Assam
Applications
TFA gear can be used within an industrial and Executive Office Precincts and IT parks, clinic working rooms, clinical isolation wards, pharmaceutical efficient zone, high priced hotels, banquet halls, conference amenities, academic campuses and top occupancy auditoriums.
For projects requiring engineered fresh-air devices, Treated Fresh Air Unit Exporters in Assam can provide configurations based on airflow, static pressure, thermal duty, filtration, energy recovery, and area conditions.
Benefits
- 100% outside fresh-air treatment
- Energy recovery through enthalpy systems
- Multi-stage filtration
- Optional HEPA and carbon filtration
- Chilled-water and DX cooling options
- Heating configuration flexibility
- Wide airflow capacity
- High-efficiency EC fan options
- Economizer loose-cooling capacity
- Custom engineering resource
For application-unique ventilation requirements, Treated Fresh Air Unit Exporter in Assam solutions may be developed throughout the project's airflow, thermal load, filtration, pressure, and power-recovery requirements.
Selection & Project Engineering
TFA preference needs to remember outside airflow, static pressure, cooling or heating duty, humidity conditions, filtration stage, heat-recovery requirement, duct design, and working temperature. EUROCON's application engineering institution can perform 3-D aerodynamic simulations, coil sizing, and motor kW calculations for custom designed requirements.
For project-specific requirements, Treated Fresh Air Unit Exporters, Assam can help configurations based on the desired CFM, static pressure, thermal capacity, filtration arrangement, and installation dimensions.
Conclusion
EUROCON SYSTEMS LLP TFA units offer a devoted outdoor-air treatment with energy recovery, filtration, cooling, heating, and dehumidification options. Their large airflow range, flexible configuration, and application-based engineering lead them to be appropriate for business, healthcare, pharmaceutical, hospitality, and academic airflow projects.