BENGALURUPRODUCTSAIR HANDLING SOLUTIONSTFA (TREATED FRESH AIR UNIT)
100% Fresh Air & Heat RecoveryDedicated Outdoor Air System (DOAS)

Treated Fresh Air Unit Manufacturers in Bengaluru

100% Fresh Air Treatment for Modern Buildings

Modern buildings want a dependable supply of treated outdoor air to hold indoor air exceptional whilst controlling temperature, humidity, and filtration. Treated Fresh Air Unit Manufacturers in Bengaluru provide dedicated outdoor-air systems designed to condition, dehumidify, and filter out 100% fresh air before it enters occupied or way regions. These devices are suitable for offices, hospitals, pharmaceutical facilities, hotels, educational buildings, and one among a type of high-occupancy environments wherein managed fresh-air ventilation is important. The airflow range is 1,000 to 50,000 CFM, with thermal duty 4.0 to 140 TR.

Airflow Range1,000 to 50,000 CFM
Max PressureUp to 1,800 Pa (7.2 in. wg)
Capacity Range4.0 TR to 140 TR
Talk to HVAC Engineer
DESIGN BENCHMARKS:Fresh Air Ventilation DesignThermal Break ConstructionEnthalpy Energy Recovery
INDUSTRIAL PLANT PHOTOGRAPHY
Treated Fresh Air Unit Manufacturers in Bengaluru
Treated Fresh Air Unit Manufacturers in Bengaluru - Showcase View 1
PLANT MANUFACTURING ASSURANCE

TFA (Treated Fresh Air Unit) — 100% Fresh Air & Energy Recovery DOAS

Each TFA (Treated Fresh Air Unit) is manufactured at Eurocon's state-of-the-art facility using CNC laser cutting, automated lock-forming, and precision structural engineering to ensure minimal casing leakage and maximum lifecycle reliability.

Heavy-Gauge Anti-Corrosive Construction (Optional)
Pre-Inspected Prior To Site Dispatch & Rigging
Constructed in Single or Double Skin Casing

Advanced Fresh Air Conditioning

A clean air unit combines filtration, cooling, dehumidification, and airflow internal one engineered device. Treated Fresh Air Unit Manufacturer in Bengaluru solutions can use 25 mm or 50 mm double-skin injected PUF insulation with a density of 40 kg/m³ and thermal-wreck aluminium profiles. Cooling may be furnished through chilled-water or DX coils, while optional heat-water coils and electric heater banks are available for heating requirements. This flexibility allows the unit to be configured according to the building's MEP design and climatic conditions.

Energy Recovery & Efficient Operation

Energy recovery can extensively improve the performance of a fresh-air airflow system by shifting strength among exhaust and incoming outdoor air. Treated Fresh Air Unit Manufacturers, Bengaluru can configure rotary total enthalpy wheels, sensible heat wheels, or run-round coil loops. The enthalpy recovery arrangement can recover up to 75% of sensible and latent exhaust energy under appropriate operating conditions. Modulating face and pass dampers can also assist economizer operation, permitting unfastened cooling while outdoor conditions are useful.

Multi-Stage Air Filtration

Fresh outdoor air can also consist of dirt, specific debris, and other contaminants that need to be addressed before distribution. Treated Fresh Air Unit Suppliers in Bengaluru can configure EU4 pre-filtration discovered by the usage of manner of EU7 or EU9 fine filtration, with optional carbon and terminal H14 HEPA filtration. This makes the system adaptable to applications where higher air cleanliness is needed. The filtration arrangement can be selected according to the indoor-air-remarkable purpose, pressure-drop allowance, device requirements, and level of protection required through the capability.

High-Performance Cooling Coils

Coil choice determines how successfully the incoming outdoor air may be cooled and dehumidified. Treated Fresh Air Unit Supplier in Bengaluru configurations use 6-row or 8-row copper-tube coils with hydrophilic fins for deep cooling applications. Chilled-water, DX refrigerant, heat-water, and electric-heater arrangements can be selected depending on the project. The devices use resource thermal capacities from 4.0 TR to 140 TR and can be designed for static pressure as much as 1,800 Pa, supporting them to serve disturbing fresh-air systems.

Flexible Fan & Motor Arrangements

Air motion wants to be matched with the desired airflow and duct resistance for reliable operation. Treated Fresh Air Unit Suppliers, Bengaluru can provide direct-drive EC plug fans or V-belt centrifugal blowers with motor capacities from 2.2 kW to 75 kW. IE3, IE4, IE5, and EC high-performance motor options are available. The operating temperature range is -10°C to +55°C ambient, while casing thickness, motor class, coil rows, and filtration banks can be custom designed normally with the project's precise specifications.

Applications Across Key Industries

Treated clean air systems are useful wherever outside air needs to be conditioned before entering into managed indoor environments. Treated Fresh Air Unit Exporters in Bengaluru can help business workplace complexes and IT parks, hospitals, surgical theatres, healthcare isolation wards, pharmaceutical system plants, cleanrooms, steeply-priced hotels, banquet halls, convention centres, instructional campuses, and high-occupancy auditoriums. The combination of deep cooling, filtration, and energy recovery makes the ones systems suitable for projects wherein fresh-air quality and strength performance need to be taken into consideration collectively.

Precision Manufacturing & Construction

Reliable performance begins with accurate casing fabrication and proper element integration. Treated Fresh Air Unit Exporter in Bengaluru solutions can be fabricated using CNC laser cutting, automatic lock-forming, and precision structural engineering. The units are available in single- or double-skin casing configurations, with optional heavy-gauge anti-corrosive construction for traumatic environments. Each unit can also be pre-inspected before net site on line dispatch and rigging, assisting make certain that the provided configuration suits the accepted project requirements before set up.

Application-Based Engineering

Every fresh-air installation has specific airflow, pressure, thermal, filtration, and dimensional requirements. Treated Fresh Air Unit Exporters, Bengaluru can grow configurations round required CFM, static pressure, thermal duty, coil arrangement, fan choice, motor potential, filtration ranges, and strength-recovery requirements. Application engineering can include 3-d aerodynamic simulations, coil sizing, and motor kW calculations. This technique allows creating a unit that works with the actual duct community and construction requirements in choosing to rely on a not unusual configuration.

Technical Specifications

ParameterSpecification
Airflow1,000–50,000 CFM
Air Volume1,700–85,000 m³/h
Static PressureMinimum 1,800 Pa
Thermal Duty4–140 TR
Casing25 / 50 mm Double-Skin, Injected PUF
PUF Density40 kg/m³
FiltrationEU4 + EU7 / EU9; Carbon / H14 HEPA Optional
Coil6 / 8-Row Copper Tubes with Hydrophilic Fins
FanDirect-Drive EC Plug Fan / V-Belt Centrifugal
Motor2.2–75 kW, IE3 / IE4 / IE5 / EC
Operating Temperature−10°C to +55°C
Energy RecoveryUp to 75% Sensible & Latent Exhaust Energy
Cooling OptionsChilled Water / DX
Heating OptionsHot Water / Electric Heater

Frequently Asked Questions

Learn More

Conclusion

A well engineered TFA unit can offer managed 100% fresh-air treatment, deep cooling, dehumidification, filtration, and energy recovery for demanding commercial and commercial environments. EUROCON SYSTEMS LLP combines precision manufacturing and application-based engineering to enlarge treated fresh-air solutions in keeping with particular assignment requirements.

CUSTOM SPECIFICATION & SIZING

NEED CUSTOM CFM, STATIC PRESSURE, OR THERMAL SIZING FOR TFA (TREATED FRESH AIR UNIT)?

Our application engineering team will run 3D aerodynamic simulations, select coil sizing, and calculate motor kW to deliver an optimized solution within 24 hours.

Consult Engineering Team

OTHER EUROCON ENGINEERED SYSTEMS

View All Solutions
Call: +91 98912 21991