TFA (Treated Fresh Air Unit) Manufacturers in Mumbai
100% Fresh Air Treatment with Energy Recovery
Treated Fresh Air Units are dedicated outside-air systems designed to condition, dehumidify, filter, and deliver easy ambient air into occupied or managed environments. Unlike conventional recirculating systems, TFA devices are specifically designed to address 100% outdoor air. They can combine deep cooling coils, multi-stage filtration, enthalpy energy recovery, and high-performance fans to enhance indoor air quality while controlling the thermal load placed at the construction's HVAC system.


TFA (Treated Fresh Air Unit) — 100% Fresh Air & Energy Recovery DOAS
Each TFA (Treated Fresh Air Unit) is manufactured at Eurocon's state-of-the-art facility using CNC laser cutting, automated lock-forming, and precision structural engineering to ensure minimal casing leakage and maximum lifecycle reliability.
What Is a Treated Fresh Air Unit?
A TFA unit is a dedicated fresh-air con system that treats outdoor air before providing it to a building or system place. The machine can remove heat and moisture, filter airborne debris, and offer conditioned airflow air according to assignment requirements.
A Treated Fresh Air Unit Manufacturers in Mumbai solution can be configured according to airflow, static pressure, cooling duty, filtration grade, outdoor temperature, energy-recovery requirements, and available installation area. This makes TFA systems appropriate for applications in which controlled clean-air going together with the flow is critical.
How TFA Units Work
Fresh outdoor air first enters the unit via the intake section. Depending on the configuration, the air passes through an enthalpy recovery wheel that transfers sensible and latent power among incoming fresh air and outgoing exhaust air. This can reduce the thermal load required to state the incoming air.
The air then passes through pre-filters and fine filters before moving across deep cooling coils. Chilled-water or DX coils can reduce temperature and humidity, while optional carbon or HEPA filtration can offer extra air treatment. An EC plug fan or centrifugal blower then materials the conditioned air to the related airflow network.
Available TFA Configurations
Enthalpy Heat Recovery
Rotary total enthalpy wheels can recover sensible and latent strength from exhaust air. The system also may be configured with sensible heat wheels or run-round coil loops.
Multi-Stage Filtration
Filtration can range from EU4 pre-filtration and EU7/EU9 fine filtration to optional chemical gas-section carbon and terminal HEPA arrangements.
Cooling & Heating Options
TFA systems can use chilled-water coils, DX refrigerant coils, hot-water coils, or electric heater banks in keeping with project requirements.
Key Features
- Airflow range: 1,000-50,000 CFM
- Cooling/thermal duty: 4.0-140 TR
- 25/50 mm injected PUF double-skin casing
- EU4 + EU7/EU9 filtration
- Optional carbon and H14 HEPA filtration
- 6-row/8-row copper-tube coils with hydrophilic fins
- Direct-drive EC plug fan or V-belt centrifugal blower
Technical Specifications
| Parameter | Specification |
|---|---|
| Airflow | 1,000–50,000 CFM |
| Air Volume | 1,700–85,000 m³/h |
| Static Pressure | Minimum 1,800 Pa |
| Thermal Duty | 4–140 TR |
| Casing | 25 / 50 mm Double-Skin, Injected PUF |
| PUF Density | 40 kg/m³ |
| Filtration | EU4 + EU7 / EU9; Carbon / H14 HEPA Optional |
| Coil | 6 / 8-Row Copper Tubes with Hydrophilic Fins |
| Fan | Direct-Drive EC Plug Fan / V-Belt Centrifugal |
| Motor | 2.2–75 kW, IE3 / IE4 / IE5 / EC |
| Operating Temperature | −10°C to +55°C |
| Energy Recovery | Up to 75% Sensible & Latent Exhaust Energy |
| Cooling Options | Chilled Water / DX |
| Heating Options | Hot Water / Electric Heater |
Applications
Commercial Offices & IT Parks
Treated fresh air units can provide devoted outdoor air to administrative center complexes and IT parks in which fresh-air airflow is wanted without placing the whole outdoor-air load on conventional room-conditioning systems.
Hospitals & Healthcare Facilities
Hospitals, surgical theatres, and isolation wards require managed airflow and filtration. TFA systems can provide treated outside air with multiple filtration ranges according to the application's air-incredible requirements.
Pharmaceutical & Cleanroom Facilities
Pharmaceutical formulations and cleanroom environments can use dedicated fresh-air systems wherein temperature, humidity, and filtration ought to be cautiously controlled.
Hotels & Convention Centers
Luxury hotels, banquet halls, and conference facilities can experience super fresh-air requirements because of occupancy versions. Treated outside air can help keep indoor comfort and airflow outstanding.
Educational Facilities
Campuses, auditoriums, and precise high-occupancy areas can gain from devoted fresh-air systems that offer controlled outside airflow while coping with thermal masses.
Benefits
When comparing a Treated Fresh Air Unit Manufacturer in Mumbai, customers need to consider airflow, outdoor-air amount, cooling and dehumidification obligation, filtration requirements, energy-recovery method, static pressure, motor performance, and running climate. The unit wants to be sized according to each air going with the flow and thermal requirements.
TFA Units for Efficient Fresh Air Management
For HVAC projects, Treated Fresh Air Unit Suppliers in Mumbai can assist with selecting suitable configurations based on building occupancy, airflow rates, weather conditions, cooling load, and filtration requirements. Technical coordination is particularly important where the TFA unit interfaces with an existing AHU or centralized air distribution system.
Treated Fresh Air Unit Exporters in Mumbai
For worldwide projects, Treated Fresh Air Unit Exporters in Mumbai need to be assessed for technical documentation, unit customization, packaging, and shipping coordination. Export requirements may also require additional attention to ambient conditions, electrical requirements, installation provisions, and fresh-air design specifications. Proper coordination helps ensure that the equipment is prepared according to the destination project's technical and logistical requirements.
How to Choose the Right TFA Unit
- 1.Calculate fresh-air requirement: Determine outside-air amount according to occupancy and airflow requirements.
- 2.Select filtration: Choose EU, carbon, or HEPA stages according to air-tremendous requirements.
Conclusion
EUROCON SYSTEMS LLP gives application-centered TFA solutions designed around fresh-air quantity, thermal duty, filtration, energy recovery, static pressure, and project-specific HVAC requirements.