HOMEPRODUCTSAIR HANDLING SOLUTIONSTFA (TREATED FRESH AIR UNIT)
100% Fresh Air & Heat RecoveryDedicated Outdoor Air System (DOAS)

TFA (Treated Fresh Air Unit)

100% Outdoor fresh air treatment units featuring total enthalpy heat recovery wheels, multi-tier filtration, and deep cooling coils.

EUROCON Treated Fresh Air (TFA) Units are purpose-built to condition, dehumidify, and filter 100% outside ambient air for modern indoor air quality (IAQ) and fresh air ventilation performance. Designed with double-skin 25mm / 50mm injected PUF insulation and thermal-break aluminum extrusions, Eurocon TFAs incorporate rotary enthalpy heat recovery wheels (recovering up to 75% sensible and latent exhaust energy), multi-stage filtration tracks (EU4 Pre, EU7 Microvee, and optional H14 HEPA), and high-efficiency deep cooling coils for maximum efficiency and fresh air purity.

Airflow Range1,000 to 50,000 CFM
Max PressureUp to 1,800 Pa (7.2 in. wg)
Capacity Range4.0 TR to 140 TR
Talk to HVAC Engineer
DESIGN BENCHMARKS:Fresh Air Ventilation DesignThermal Break ConstructionEnthalpy Energy Recovery
INDUSTRIAL PLANT PHOTOGRAPHY
TFA (Treated Fresh Air Unit) - View 1
TFA (Treated Fresh Air Unit) Industrial Showcase Angle 1
PLANT MANUFACTURING ASSURANCE

TFA (Treated Fresh Air Unit) — 100% Fresh Air & Energy Recovery DOAS

Each TFA (Treated Fresh Air Unit) is manufactured at Eurocon's state-of-the-art facility using CNC laser cutting, automated lock-forming, and precision structural engineering to ensure minimal casing leakage and maximum lifecycle reliability.

Heavy-Gauge Anti-Corrosive Construction (Optional)
Pre-Inspected Prior To Site Dispatch & Rigging
Constructed in Single or Double Skin Casing
TECHNICAL MATRIX

ENGINEERING PARAMETERS & PERFORMANCE RATINGS

Engineered and manufactured according to international HVAC engineering best practices.

Airflow Capacity
1,000 to 50,000 CFM (1,700 to 85,000 m³/h)
Static Pressure Rating
Up to 1,800 Pa (7.2 in. wg)
Cooling / Thermal Duty
4.0 TR to 140 TR (Chilled Water / DX Coil)
Casing & Insulation
25mm / 50mm Double-Skin PUF Injected (40 kg/m³) with Thermal Break Profile
Filtration Matrix
EU4 Pre-Filter + EU7/EU9 Fine Filter + Carbon / HEPA Optional
Coil Construction
6-Row / 8-Row Copper Tubes with Hydrophilic Fins
Drive & Motor System
Direct-Drive EC Plug Fan / V-Belt Centrifugal2.2 kW to 75 kW (IE3/IE4/IE5 / EC High Efficiency)
Operating Temperature
-10°C to +55°C Ambient
MODULAR FLEXIBILITY

CUSTOM CONFIGURATION OPTIONS

Tailor casing thickness, motor classes, coil rows, and filtration banks to meet exact MEP specifications.

Enthalpy Wheel

Energy Recovery

Rotary total enthalpy wheel, sensible heat wheel, or run-around coil loop.

Configurable in RFQ
EU4 to HEPA

Filtration Grade

EU4 Pre + EU7/EU9 Fine + Chemical Gas-Phase Carbon or Terminal HEPA.

Configurable in RFQ
CW / DX / Heat

Cooling & Heating

Chilled Water coil, DX refrigerant coil, hot water coil, or electric heater bank.

Configurable in RFQ
Economizer

Bypass Dampers

Modulating face & bypass dampers for economizer free-cooling operation.

Configurable in RFQ
APPLICATIONS

PRIMARY INDUSTRIAL & COMMERCIAL ENVIRONMENTS

Commercial Office Complexes & IT Parks (Fresh Air Ventilation Standards)
Hospitals, Surgical Theaters & Healthcare Isolation Wards
Pharmaceutical Formulations & Cleanroom Conditioning
Luxury Hotels, Banquet Halls & Convention Centers
Educational Campuses & High-Occupancy Auditoriums
CUSTOM SPECIFICATION & SIZING

NEED CUSTOM CFM, STATIC PRESSURE, OR THERMAL SIZING FOR TFA (TREATED FRESH AIR UNIT)?

Our application engineering team will run 3D aerodynamic simulations, select coil sizing, and calculate motor kW to deliver an optimized solution within 24 hours.

Consult Engineering Team

OTHER EUROCON ENGINEERED SYSTEMS

View All Solutions
Call: +91 98912 21991