KERALAPRODUCTSAIR HANDLING SOLUTIONSAIR HANDLING UNIT (AHU)
Modular Double-Skin Series

Air Handling Unit Manufacturers in Kerala

Efficient Air Washers for Cooling and Air Treatment

Today's AHU is an included unit combining air filtration, thermal treatment, fan performance, and controlled air distribution in an single system. Air Handling Unit Manufacturers In Kerala can produce modular systems for residential and industrial centres where regular airflow and temperature-controlling indoor environments are important. EUROCON AHUs can function at static pressures up to 2,000 Pa from 400 to 40,000 CFM. We offer cooling or thermal duty ranging from oneZero to 100 TR with each DX and chilled-water configurations.

Airflow Range400 to 40,000 CFM
Max PressureUp to 2,000 Pa (8.0 in. wg)
Capacity Range1.0 TR to 100 TR
AVAILABLE IN:
DX AHUDirect Expansion System
CHILLED WATER AHUChilled Water System
Talk to HVAC Engineer
DESIGN BENCHMARKS:Thermal Break ConstructionHigh Efficiency Plug FanLow Acoustic Profile
INDUSTRIAL PLANT PHOTOGRAPHY
Air Handling Unit Manufacturers in Kerala
Air Handling Unit Manufacturers in Kerala - Showcase View 1
PLANT MANUFACTURING ASSURANCE

AHU (DX Type System) — Modular Double-Skin Construction

Modular thermal-break extruded aluminum profiles with 25mm / 50mm high-density injected PUF (40 kg/m³) panels, factory-fitted Direct Expansion (DX) cooling coil connections, multi-stage EU4 to HEPA filtration tracks, and high-efficiency fan section.

Heavy-Gauge Anti-Corrosive Construction (Optional)
Pre-Inspected Prior To Site Dispatch & Rigging
Constructed in Single or Double Skin Casing

Understanding Air Handling Units

An AHU attracts air in the room, after which flows through a selected set of air handlings and conditioning degrees, before discharging the handled air via the related ductwork. Such an apparatus can be customized to be included in offices, studios, healthcare amenities, cleanrooms, production areas, and special regulated surroundings.

For such installations, an Air Handling Unit Manufacturer in Kerala can provide direct-drive EC motor plug fans, backward-curved plug fans, or V-belt centrifugal systems. Motor ratings are available from 1.5 to 90 kW, with IE3, IE4, IE5, and EC brushless performance options.

Casing, Thermal Break & Insulation

AHU case using thermal damage extruded aluminum profiles and injected PUF insulation. The 25 mm and 50 mm panel options with PUF of 40 kg/m help to support thermal performance when minimizing condensation, thermal bridging, acoustic transmission and preferred air leakage.

Where the application calls for extra resistance to the surrounding environment, Air Handling Unit Manufacturers, Kerala can provide heavy-gauge anti-corrosive manufacturing. The casing may be provided as a single- or double-skin arrangement based on the project requirement.

Air Handling Unit Suppliers in Kerala

Fan, Coil & Filtration Options

Filtration can be organized in multiple stages, beginning with an EU4 pre-filter and placed by manner of EU7 or EU9 Microvee filtration. HEPA H13/H14 filtration is available for applications requiring higher filtration ranges. Cooling coils use copper tubes with hydrophilic aluminum fins, while whole. Copper-copper construction may be selected for corrosive environments.

For application-specific requirements, Air Handling Unit Suppliers in Kerala can customize the fan segment, coil production, filtration banks, casing thickness, and motor class. Differential-pressure transmitters may be production units calibrated for computerized VAV CFM remarks.

Key Features

  • 400-40,000 CFM airflow
  • Up to 2,000 Pa static pressure
  • 1-100 TR cooling/thermal duty
  • Chilled-water and DX configurations
  • 25 mm / 50 mm PUF insulated panels
  • Thermal-harm aluminum profiles
  • EU4 to EU9 filtration options
  • Optional HEPA H13/H14 filters
  • Hydrophilic aluminum-fin cooling coils
  • Full copper-copper coil opportunity
  • EC and plug-fan technology
  • IE3 / IE4 / IE5 / EC motors
  • Factory-calibrated airflow monitoring

This flexibility makes an Air Handling Unit Supplier in Kerala appropriate for projects requiring unique mixtures of cooling, filtration, airflow management, and air-distribution performance.

Technical Specifications

ParameterSpecification
Airflow Capacity400–40,000 CFM
Airflow Volume680–68,000 m³/h
Static PressureUp to 2,000 Pa
Cooling / Thermal Duty1–100 TR
Casing25 / 50 mm Double Skin
PUF Density40 kg/m³
FiltrationEU4 + EU7 / EU9; H13 / H14 Optional
CoilCopper Tubes + Hydrophilic Aluminium Fins
Fan OptionsEC Plug Fan / Backward-Curved Plug Fan / V-Belt Centrifugal
Motor1.5–90 kW
Motor EfficiencyIE3 / IE4 / IE5 / EC
Operating Temperature−15°C to +65°C
Cooling SystemsChilled Water / DX

The available specs permit Air Handling Unit Suppliers, Kerala to pick out the proper mixture of airflow, pressure, thermal duty, filtration, coil construction, fan type, and motor performance for each project.

Air Handling Unit Exporters in Kerala

Applications

These AHUs are designed for environments which consist of pharmaceutical manufacturing, sterile cleanrooms, hospitals, operation theatres, important healthcare regions, IT parks, business headquarters, high-rise buildings, data centres, semiconductor facilities, electronics assembly, precision laboratories, battery production, and automobile plants.

For huge HVAC and industrial duties, Air Handling Unit Exporters in Kerala can provide configurations based on the required airflow, cooling duty, static pressure, filtration level, coil material, motor performance, and available in the installation area.

Benefits

  • Precise air treatment and distribution
  • Flexible cooling configurations
  • Multi-stage filtration capacity
  • HEPA filtration possibility
  • Energy-efficient EC motor options
  • Low-leakage double-skin casing
  • Thermal-break manufacturing
  • Corrosion-resistant construction possibility
  • Flexible coil metallurgy
  • Project-specific sizing

For facilities with unique environmental or way requirements, Air Handling Unit Exporter in Kerala solutions may be superior around the required air amount, thermal load, pressure, filtration, and operating conditions.

Selection & Project Supply

Choosing an AHU includes comparing the required CFM, static pressure, cooling or thermal duty, filtration level, coil material, motor performance, casing manufacturing, and operating temperature. The preference wants to also account for the available mechanical-room or plant place and the related duct arrangement.

For customized installations, Air Handling Unit Exporters, Kerala can help with technical sizing and configuration. EUROCON's application engineering technique consists of 3-D aerodynamic simulations, coil sizing, and motor kW calculations for developing an optimized AHU.

FAQs

Learn More

Conclusion

EUROCON SYSTEMS LLP AHUs are modular air-treatment systems designed for controlled cooling, filtration, and air distribution throughout of industrial, healthcare, pharmaceutical, commercial, and generation centers. Their flexible casing, fan, coil, filtration, and motor configurations allow each unit to be advanced across the performance requirements of the installation.

CUSTOM SPECIFICATION & SIZING

NEED CUSTOM CFM, STATIC PRESSURE, OR THERMAL SIZING FOR AIR HANDLING UNIT (AHU)?

Our application engineering team will run 3D aerodynamic simulations, select coil sizing, and calculate motor kW to deliver an optimized solution within 24 hours.

Consult Engineering Team

OTHER EUROCON ENGINEERED SYSTEMS

View All Solutions
Call: +91 98912 21991