KERALAPRODUCTSAIR HANDLING SOLUTIONSTFA (TREATED FRESH AIR UNIT)
100% Fresh Air & Heat RecoveryDedicated Outdoor Air System (DOAS)

Treated Fresh Air Unit Manufacturers in Kerala

Outdoor Air Systems for Controlled Fresh-Air Supply

Buildings that require a regular delivery of conditioned outside air want more than a general ventilation fan. Treated Fresh Air Unit Manufacturers in Kerala can supply devoted outside-air systems that filter, cool, dehumidify, and situation 100% fresh air before distribution. EUROCON TFA devices are available from 1,000 to 50,000 CFM, with static pressure up to 1,800 Pa and thermal capability from 4.0 TR to 140 TR.

Airflow Range1,000 to 50,000 CFM
Max PressureUp to 1,800 Pa (7.2 in. wg)
Capacity Range4.0 TR to 140 TR
Talk to HVAC Engineer
DESIGN BENCHMARKS:Fresh Air Ventilation DesignThermal Break ConstructionEnthalpy Energy Recovery
INDUSTRIAL PLANT PHOTOGRAPHY
Treated Fresh Air Unit Manufacturers in Kerala
Treated Fresh Air Unit Manufacturers in Kerala - Showcase View 1
PLANT MANUFACTURING ASSURANCE

TFA (Treated Fresh Air Unit) — 100% Fresh Air & Energy Recovery DOAS

Each TFA (Treated Fresh Air Unit) is manufactured at Eurocon's state-of-the-art facility using CNC laser cutting, automated lock-forming, and precision structural engineering to ensure minimal casing leakage and maximum lifecycle reliability.

Heavy-Gauge Anti-Corrosive Construction (Optional)
Pre-Inspected Prior To Site Dispatch & Rigging
Constructed in Single or Double Skin Casing

How a TFA Unit Works

A handled fresh air unit attracts outside air into the system and passes it through filtration and thermal-treatment levels before presenting it to the construction. Depending on the project, the device also can recover energy from exhaust air to reduce the burden on the cooling device.

For industrial and business airflow projects, a Treated Fresh Air Unit Manufacturer in Kerala can configure the system with rotary enthalpy recovery, deep cooling coils, fine filters, carbon filtration, or HEPA filtration. The rotary enthalpy machine can recover up to 75% sensible and latent exhaust power.

Casing, Insulation & Manufacturing

EUROCON TFA devices are built using single- or double-skin casing options. Double-skin fashions use 25 mm or 50 mm injected PUF insulation at 40 kg/m³, collectively with thermal-destroyed aluminum profiles.

The units are synthetic through CNC laser cutting, automatic lock-forming, and precision structural engineering. Treated Fresh Air Unit Manufacturers, Kerala can also provide heavy-gauge anti-corrosive manufacturing when additional resistance is needed for the working environment.

Treated Fresh Air Unit Suppliers in Kerala

Energy Recovery, Filtration & Thermal Treatment

Energy-recovery options include a rotary overall enthalpy wheel, sensible heat wheel, or run-round coil loop. The filtration arrangement can combine EU4 pre-filtration with EU7/EU9 pleasant filtration, while carbon or terminal HEPA degrees can be introduced for specialized air-specific requirements.

For buildings with different heating and cooling desires, Treated Fresh Air Unit Suppliers in Kerala can configure chilled-water coils, DX refrigerant coils, hot-water coils, or electric heater banks. Modulating face and skip dampers also are available for economizer operation.

Major Features

  • Airflow from 1,000-50,000 CFM
  • 1,700-85,000 m³/h airflow extent
  • Static pressure up to 1,800 Pa
  • 4.0-140 TR thermal duty
  • 25/50 mm double-skin PUF insulation
  • PUF density of 40 kg/m³
  • Thermal-ruin profile production
  • EU4, EU7 and EU9 filtration options
  • Carbon and HEPA filtration options
  • 6-row/8-row copper-tube coils
  • Hydrophilic coil fins
  • EC plug fan and V-belt centrifugal fan options
  • 2.2-75 kW motors
  • IE3/IE4/IE5/EC performance options
  • Ambient operation from -10°C to +55°C

This configuration range allows a Treated Fresh Air Unit Supplier in Kerala to choose the suitable combination of air quantity, pressure, filtration, thermal potential, fan, and strength-recovery era.

Technical Specifications

ParameterSpecification
Airflow1,000–50,000 CFM
Air Volume1,700–85,000 m³/h
Static PressureMinimum 1,800 Pa
Thermal Duty4–140 TR
Casing25 / 50 mm Double-Skin, Injected PUF
PUF Density40 kg/m³
FiltrationEU4 + EU7 / EU9; Carbon / H14 HEPA Optional
Coil6 / 8-Row Copper Tubes with Hydrophilic Fins
FanDirect-Drive EC Plug Fan / V-Belt Centrifugal
Motor2.2–75 kW, IE3 / IE4 / IE5 / EC
Operating Temperature−10°C to +55°C
Energy RecoveryUp to 75% Sensible & Latent Exhaust Energy
Cooling OptionsChilled Water / DX
Heating OptionsHot Water / Electric Heater

With the ones specifications, Treated Fresh Air Unit Suppliers, Kerala can help super airflow layouts and fresh-air treatment requirements across industrial, healthcare, hospitality, pharmaceutical, and educational buildings.

Treated Fresh Air Unit Exporters in Kerala

Where TFA Units Are Used

TFA systems are designed for industrial office complexes, IT parks, hospitals, surgical theatres, healthcare isolation wards, pharmaceutical system facilities, cleanrooms, luxury hotels, ceremonial dinner halls, convention centres, academic campuses, and high-occupancy auditoriums.

For engineered airflow projects, Treated Fresh Air Unit Exporters in Kerala can offer systems configured across the project's airflow, pressure, cooling duty, filtration grade, strength-recovery approach, and installation requirements.

Key Benefits

  • Controlled outdoor-air delivery
  • 100% fresh-air treatment
  • Sensible and latent energy recovery
  • Multi-stage filtration
  • Optional carbon and HEPA degrees
  • Flexible cooling and heating arrangements
  • High-performance fan options
  • Economizer unfastened-cooling assist
  • Wide potential range
  • Custom engineering and sizing

For demanding fresh-air applications, Treated Fresh Air Unit Exporter in Kerala solutions may be evolved across the desired air volume, thermal duty, pressure, filtration level, and heat-recovery configuration.

Selection & Engineering

A suitable TFA unit ought to be determined according to outdoor-air quantity, cooling load, static pressure, filtration requirement, humidity control, energy-recovery desires, operating temperature, and duct arrangement. EUROCON's application engineering team can carry out 3-D aerodynamic simulations, coil sizing, and motor kW calculations for project-unique requirements.

For customized MEP requirements, Treated Fresh Air Unit Exporters, Kerala can assist configurations based on the desired airflow, thermal potential, filtration arrangement, fan selection, energy recovery, and dimensional requirements.

FAQs

Learn More

Conclusion

EUROCON SYSTEMS LLP TFA units are designed for buildings that require managed treatment of 100% outdoor air. With energy recovery, multi-stage filtration, cooling and heating options, efficient fan systems, and custom engineering, the units can be tailor-made for healthcare, commercial, pharmaceutical, hospitality, and educational applications.

CUSTOM SPECIFICATION & SIZING

NEED CUSTOM CFM, STATIC PRESSURE, OR THERMAL SIZING FOR TFA (TREATED FRESH AIR UNIT)?

Our application engineering team will run 3D aerodynamic simulations, select coil sizing, and calculate motor kW to deliver an optimized solution within 24 hours.

Consult Engineering Team

OTHER EUROCON ENGINEERED SYSTEMS

View All Solutions
Call: +91 98912 21991